MD 9210 Mini Clamp Meter

Clamp meters

Versatility, sturdy case, high accuracy and lots of measurement functions are key features of the current clamp MD 9210. This universal current clamp offers good value for money.

Sets

Standards applied

Instrument safety towards user

  • IEC/EN 61000 Electromagnetic compatibility (EMC) series
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
  • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 2004/108/EC on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
  • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Properties

Measuring functions

  • AC, DC voltage measurement;
  • AC current measurement;
  • Frequency measurement;
  • Resistance measurement;
  • Continuity testing;
  • Capacitance measurement;
  • Diode test.

Key features

  • Jaw size: 26 mm.
  • Lightweight: 139 g only.
  • High specification: readings up to 600 A with excellent accuracy.
  • Auto-ranging: no need of manual ranging.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • Data Hold: data hold feature freezes the display for later view.
  • MAX Hold: MAX hold feature freezes the maximum measured value.
  • Easy to read: large bright 3-3/4 digits 4000 counts LCD display.

Technical data

  • Dimensions (w x h x l): 63 x 32 x 190 mm
  • Mass (without accessories): 139 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Voltage detection
  • Field service
  • Electronics

General purpose

  • Home maintenance
  • Hobby work

Specifications

Downloads

Type File Language Version Release Notes Type Size View Download
Datasheet MD 9210 Mini Clamp Meter en 1.0 19.01.2011 pdf 199.69 KB
Manual MD 9210 Mini Clamp Meter Multi-Language 1.3.4 09.09.2022 20 751 290 pdf 2.14 MB Login
DoC EU Declaration of Conformity Multi-Language 10.08.2021 QR code External link Unknown