MI 3125 EurotestCOMBO

Multifunctional testers

The MI 3125 EurotestCOMBO is the appropriate instrument for the installation safety testing on TT and TN systems. The large graphic display with backlight offers easy reading of results, indications, measurement parameters and messages. Two LED Pass / Fail indicators are placed on both sides of the LCD. EurotestCOMBO contains integrated characteristics of fuses and RCDs for the evaluation of test results. The handling of the instrument is designed to be as simple and clear as possible. Each test has its own individual help screen describing how to connect the instrument into the installation and how to perform a measurement. MI 3125 EurotestCOMBO performs continuity, insulation, RCD, loop, line, voltage,frequency and phase sequence tests required by the EN 61557 standard.

Select a set

Standards applied

Building LV Installation

  • EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
  • EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
  • IEC/EN 60364 Electrical Installations for Buildings series
  • IEC/EN 60364-6 Electrical Installations for Buildings - Verification
  • IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock
  • IEC/EN 60364-5-52 Electrical Installations for Buildings - Wiring system
  • IEC/EN 60755 General safety requirements for residual current operated protective devices
  • IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
  • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
  • IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
  • IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
  • VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
  • AS / NZ 3017 Electrical installations – Verification guidelines
  • AS / NZ 3018 Electrical installations - Domestic installations
  • BS 7671 IEE Wiring Regulations (18th edition)
  • CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC current

Earthing and lightning protection 

  • LPSinsp Competences: Lightning Protection of Buildings Inspection
  • LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
  • IEC 62305 Protection against lightning - series

Instrument safety towards user

  • Directive EMC 89/336/EE on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series

Properties

Measuring functions

  • Insulation resistance with DC voltage;
  • Continuity of PE conductors with 200 mA test current with polarity change;
  • Line impedance;
  • Loop impedance;
  • Loop impedance with Trip Lock RCD function;
  • TRMS voltage and frequency;
  • Phase sequence;
  • RCD testing (general and selective, type AC, A);
  • Earth resistance (3-wire method).

Key features

  • LED Pass/Fail indicators: two LED indicators for PASS / FAIL evaluation of test results are placed on both sides of the LCD.
  • Help screens: instrument comes complete with built-in help screens for referencing on site.
  • Earth resistance measurement: instrument performs 3-wire earth resistance testing with two additional rods.
  • Built-in fuse tables: this unique feature allows automatic evaluation of the line / loop impedance compared to the regulations.
  • Online voltage monitoring: monitors all 3 voltages in real-time.
  • Upgradeable: if changes occur to the regulations, upgrades can be made to the firmware to keep the unit up to date.
  • Polarity swap: automatic polarity reversal on continuity test.
  • Insulation range: wide range of insulation test voltages from 50 V to 1000 V, reading up to 1000 MΩ.

Technical data

  • Dimensions (w x h x l): 230 x 140 x 80 mm
  • Mass (without accessories): 1.0 kg

Applications

Preventative maintenance

  • Earth continuity and insulation testing
  • Line and loop impedance and RCD testing
  • Basic earth resistance
  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Installation troubleshooting

Specifications

Downloads

Datasheet Language Version Release Notes Type Size Download
MI 3125 EurotestCOMBO en 1.0 28.01.2016 pdf 378.76 KB
Manual Language Version Release Notes Type Size Download
MI 3125 BT EurotestCOMBO en 2.7.10 23.01.2023 20 751 484 pdf 2.7 MB Login
Fuse tables guide en 1.11.1 20.01.2023 pdf 350.79 KB Login
DoC Language Version Release Notes Type Size Download
UK Declaration of Conformity uk 02.09.2022 QR code External link Unknown

Where to buy?

Search for distributors and partners

Have a question?

Speak with a specialist