MD 9880 is the ultimate troubleshooting tool. Combining essential multimeter functions with thermal viewer, it allows a service provider to quickly locate a wide array of possible faults. Hot spots can be then simply tested with electrical measurement. Thermal view also expands the usefulness of the instrument to other applications in the facility or vehicle, locating leaks, frictions stress and thermal losses.
Do you own this product?
Which is the best for you?
Select a set
Videos
Promotional
Properties
Measuring functions
- Temperature with cursor on camera,
- TRMS DC and AC voltage,
- TRMS DC and AC current,
- Resistance,
- Frequency,
- Capacitance,
- Duty cycle,
- Diode test.
Key features
- Thermal view,
- Automatic and manual range,
- Hold and auto-hold modes,
- MIN/MAX values capture,
- Relative mode,
- Peak capture mode,
- Temperature in °C, °F or K,
- PC software.
Technical data
- Dimensions (w x h x l): 175 x 85 x 55 mm
- Mass (without accessories): 540
Applications
Power generation
- Testing contacts of high voltage energy switches and bonding resistances
Power distribution
- Insulation of long cables
- DC Networks’ and Power Sources’ Line and Loop Resistances
Industrial installations
- Grid impedance and automatic trip-out ability
- Specific earth resistance measurement methods
- Earth leakage relay and fault currents
- Using thermography in electrical installations
Low voltage electrical installation safety
- Mains bonding and touch voltages during fault
- Switchboards and automatic trip-out protection
Low voltage earthing and lightning protection
- Surge protection devices
Low voltage power quality
- Uninterruptible power supply
- Power quality reports
- Effects of power quality issues on living and working environment
Special locations
- Wet and outdoor locations
- IT system
- Low voltage photovoltaic installations
- DC installations
- EVSE construction and testing
Mobile installations
- Vehicles with an on-board generator
- Emergency response vehicles
- Telecommunication equipment in mobile installations
Portable and fixed appliances
- PAT measurements and management
Hospital earthing and lightning protection
- Surge protection devices in hospitals
Power supply and power distribution
- Hospital switchboards and automatic trip-out protection
- Power quality
Surgery rooms or operating theatres
- Medical IT system
- Isolated areas RCDs
- Medical devices
Patient recovery rooms and hospital wards
- Public and workspace electrical safety in healthcare
Secondary power sources in healthcare
- Generator safety
- Ambulances
Preventative maintenance
- Basic earth resistance
- Voltage measurements
- Current measurements
Troubleshooting
- Photovoltaic systems
- Phase sequence detection
- Field service
General purpose
- Home maintenance
Specifications
Where to buy?
Search for distributors and partners
Have a question?
Speak with a specialist