• Home
  • Products
    • Electrical Installations Safety
      • Multifunctional testers
      • Photovoltaic and electrical installation testers
      • Single-functional testers
      • Other instruments / adapters / accessories
    • High Voltage Insulation / Continuity / Earth / Transformer
      • Earth testers
      • Transformer testers
      • Continuity testers
      • High voltage insulation testers
    • Machines / Appliances / Switchgear Safety
      • PAT testers
      • Machine and switchboard testers
      • Medical testers
      • End-of-line safety testing in production
      • Other Instruments / adapters / accessories
    • Power Quality Analysis
      • Class A power quality analysers
      • Class S power quality analysers
      • Power calibrator/simulator
    • Equipment for Laboratories and Schools
      • Demonstration boards LV
      • Demonstration boards EE
      • Power supply & other units
    • Digital Multimeters / Current Clamps / Voltage Testers / Thermal cameras
      • Digital multimeters
      • Clamp meters
      • Thermal cameras
      • Voltage and continuity tester
      • Non contact voltage detectors
    • Software
      • PC Software
      • Android
    • Transformers
  • Applications
    • Electrical Energetics
      • Power generation
      • Renewable energy sources
      • Power distribution
      • Industrial installations
    • Building Facilities
      • Low voltage electrical installation safety
      • Low voltage earthing and lightning protection
      • Low voltage power quality
      • Special locations 
    • Electrical Equipment
      • Machines safety
      • Portable and fixed appliances 
      • End-of-line safety testing in production
    • Transportation
      • e-Mobility
      • Mobile installations
      • Railways
      • Airports
      • Harbours and ships
    • Medical Facilities
      • Hospital earthing and lightning protection 
      • Power supply and power distribution 
      • Surgery rooms or operating theatres
      • Patient recovery rooms and hospital wards
      • Secondary power sources in healthcare
  • Try & Buy
    • Distributors
    • Events
  • Downloads
    • Product-related downloads
    • Catalogues and brochures
    • Documentation center
  • Support
    • Repair
    • Calibration
    • RMA
    • RMA tracking
    • FAQ
    • Technical support
    • Academy
    • Newsletter
  • New
    • NEW product: MI 3281 WR Analyser
    • NEW product: MD 9273 Bluetooth TRMS leakage clamp with power functions
    • NEW product: MD 9055 TRMS Advanced Multimeter
    • NEW product: MI 3288 Earth Insulation Tester
    • Show all
  • EN
    • UK
    • DE
    • ES
    • SI
    • LT
      Only Product Finder
    • RU
      Only Product Finder
    • CZ
      Only Product Finder
    • SK
      Only Product Finder
    • PL
      Only Product Finder
    • HU
      Only Product Finder
  • Find Us
  • Contact Us
Forgot password?
Don't have an account yet? Register.

No items in inquiry

  • Products
    Groups (9 items)
    Electrical Installations Safety
    High Voltage Insulation / Continuity / Earth / Transformer
    Machines / Appliances / Switchgear Safety
    Power Quality Analysis
    Equipment for Laboratories and Schools
    Digital Multimeters / Current Clamps / Voltage Testers / Thermal cameras
    Software
    Transformers
    Sub groups (4 items)
    Multifunctional testers
    Photovoltaic and electrical installation testers
    Single-functional testers
    Other instruments / adapters / accessories

    Multifunctional testers

    Electrical Installations Safety

    Comprehensive electrical installation safety testing

    Read more
    Products (7 items)
    MI 3155 EurotestXD
    MI 3152H EurotestXC 2,5 kV
    MI 3152 EurotestXC
    MI 3102H BT EurotestXE 2,5 kV
    MI 3102 BT EurotestXE
    MI 3100 SE EurotestEASI
    MI 3125 BT EurotestCOMBO
  • Solutions
    Areas (5 items)
    Electrical Energetics
    Building Facilities
    Electrical Equipment
    Medical Facilities
    Applications (4 items)
    Power generation
    Renewable energy sources
    Power distribution
    Industrial installations

    Power generation

    Electrical Energetics

    Electrical properties and challenges in power generation units

    Read more
    Application Notes (6 items)
    Earthing and lightning protection in thermal energy power plants
    Using disconnected transmission lines in ground resistance measurements
    Single flex clamp method for testing building construction integrity for lightning protection
    Testing contacts of high voltage energy switches and bonding resistances
    Power quality analysis in medium voltage facilities
    What is power factor
  • Try & Buy
    • Distributors Events
  • Downloads
    • Product-related downloads Catalogues and brochures Documentation center
  • Support
    • Repair
    • Calibration
    • RMA
    • RMA tracking
    • FAQ
    • Technical support
    • Academy
    • Newsletter
  • About
    • Company profile
    • Company structure
    • Milestones
    • Certificates
  • Login
  • EN
    • UK
    • DE
    • ES
    • SI
    • LT
      Only Product Finder
    • RU
      Only Product Finder
    • CZ
      Only Product Finder
    • SK
      Only Product Finder
    • PL
      Only Product Finder
    • HU
      Only Product Finder
EN
  • UK
  • DE
  • ES
  • SI
  • LT
    Only Product Finder
  • RU
    Only Product Finder
  • CZ
    Only Product Finder
  • SK
    Only Product Finder
  • PL
    Only Product Finder
  • HU
    Only Product Finder
  • Login
Product Finder

Extra Features

Main Features

Additional Features

Special Accessories

  • All product groups
    Product groups
    • All product groups
    • Electrical Installations Safety
      • Multifunctional testers
      • Photovoltaic and electrical installation testers
      • Single-functional testers
      • Other instruments / adapters / accessories
    • High Voltage Insulation / Continuity / Earth / Transformer
      • Earth testers
      • Transformer testers
      • Continuity testers
      • High voltage insulation testers
    • Machines / Appliances / Switchgear Safety
      • PAT testers
      • Machine and switchboard testers
      • Medical testers
      • End-of-line safety testing in production
      • Other Instruments / adapters / accessories
    • Power Quality Analysis
      • Class A power quality analysers
      • Class S power quality analysers
      • Power calibrator/simulator
    • Equipment for Laboratories and Schools
      • Demonstration boards LV
      • Demonstration boards EE
      • Power supply & other units
    • Digital Multimeters / Current Clamps / Voltage Testers / Thermal cameras
      • Digital multimeters
      • Clamp meters
      • Thermal cameras
      • Voltage and continuity tester
      • Non contact voltage detectors
    • Software
      • PC Software
      • Android
  • All applications
    Applications
    • All applications
    • Electrical Energetics
      • Power generation
      • Renewable energy sources
      • Power distribution
      • Industrial installations
    • Building Facilities
      • Low voltage electrical installation safety
      • Low voltage earthing and lightning protection
      • Low voltage power quality
      • Special locations 
    • Electrical Equipment
      • Machines safety
      • Portable and fixed appliances 
      • End-of-line safety testing in production
    • Transportation
      • e-Mobility
      • Mobile installations
    • Medical Facilities
      • Hospital earthing and lightning protection 
      • Power supply and power distribution 
      • Surgery rooms or operating theatres
      • Patient recovery rooms and hospital wards
      • Secondary power sources in healthcare
    • Other applications
      • Preventative maintenance
      • Troubleshooting
      • General purpose
  • All standards
    Standards Applied
    • All standards
    • Earthing and lightning protection 
      • LPSinsp Competences: Lightning Protection of Buildings Inspection
      • LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
      • IEC 62305 Protection against lightning - series
      • IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
      • IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
    • Power quality 
      • PQA Competences: Power Quality Analyzing & Reporting
      • IEC/EN 61000-4-15 Electromagnetic compatibility (EMC) – Part 4: Testing and measurement techniques – Section 15: Flickermeter – Functional and design specifications
      • IEC/EN 61000-4-30 Ed. 3.0 Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
      • IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring devices (PMD)
      • IEC 62586-1 Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)
      • IEC 62586-2 Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements
      • IEEE 1459-2010 IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions
      • GOST 33073-2014 Electric energy. Electromagnetic compatibility of technical equipment. Control and monitoring of electric power quality in the public power supply systems
      • NRS 048 ELECTRICITY SUPPLY-QUALITY OF SUPPLY
      • GOST R 54149: 2010 Electric energy. lectromagnetic compatibility of technical equipment. Power quality limits in the public power supply systems
      • IEEE 519 Recommended Practice and Requirements for Harmonic Control in Electric Power Systems
      • EN 50160 Voltage characteristics of electricity supplied by public distribution networks
    • Earthing and Grounding
      • EES Competences: Electrical Energetic Systems Earthing and Grounding Safety
      • HD 637 S1 Power installations exceeding 1 kV a.c.
      • IEEE Guide for Safety in AC Substation Grounding
      • IEEE 81-2012 IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System
      • IEEE 142 Recommended Practice for Grounding of Industrial and Commercial Power Systems
      • IEEE 367-2012 - IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault
      • EN 50522 Earthing of power installations exceeding 1 000 V a.c.
      • RAT 2008 Spanish high-voltage regulation
    • Electrical Energetics
      • EEA Competences: Electrical Energetic Installations with Automatic Trip-Out Ability
      • IEC 60076-1 Power transformers Part 1: General
      • IEC/EN 60909-0 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
      • IEC / EN 60947-2 Low-voltage switchgear and controlgear – Part 2: Circuit-breakers
      • IEC 61869-2 Instrument transformers Part 2: Additional requirements for current transformers
      • IEEE C57.12.90 Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
      • ASTM B 539 Standard Test Methods for measuring Resistance of Electrical connections (Static Contacts)
      • NMEA AB 4-2009 Guidelines for Inspection and Preventive Maintenance of Molded-Case Circuit Breakers Used in Commercial and Industrial Applications
      • El Real Decreto 223/2008 Regulation on technical conditions and safety guarantees in high voltage power lines and their complementary technical instructions ITC-LAT 01 to 09
    • Photovoltaic systems
      • PVV Competences: Photo Voltaic Installations Safety/Quality
      • IEC / HD 60364-7-712 Low Voltage Electrical Installation Safety - Special installtions and locations
      • IEC/EN 62446 Photovoltaic (PV) systems - Requirements for testing, documentation and maintenance
      • IEC/EN 61829 Crystalline silicon photovoltaic (PV) array – On-site measurement of I / V characteristics
    • Building LV Installation
      • EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
      • EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
      • IEC/EN 60364 Electrical Installations for Buildings series
      • IEC/EN 60364-6 Electrical Installations for Buildings - Verification
      • IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock
      • IEC/EN 60364-5-52 Electrical Installations for Buildings - Wiring system
      • IEC/EN 60755 General safety requirements for residual current operated protective devices
      • IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
      • IEC/EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)
      • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
      • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - relevant parts
      • IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
      • IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
      • IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
      • IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
      • IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
      • IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
      • IEC/EN 61557-11 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCM) in TT, TN and IT systems
      • IEC/EN 60364-7 Electrical Installations for Buildings - Requirements for special installations or locations
      • VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
      • AS / NZ 3017 Electrical installations – Verification guidelines
      • AS / NZ 3018 Electrical installations - Domestic installations
      • BS 7671 IEE Wiring Regulations (18th edition)
      • CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC current
    • Electrical switchboards safety
      • ESB Competences: Electrical Switchboards Safety Testing
      • IEC/EN 61439-1 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
      • IEC/EN 62271 High-voltage switchgear and controlgear - series
      • IEC/EN 62271-1 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
      • IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
    • Machine safety
      • MST Competences: Machines Electrical Safety Testing
      • IEC/EN 50191 Erection and operation of electrical test equipment
      • IEC/EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
      • IEC/EN 62368-1 Audio/video, information and communication technology equipment - Part 1:Safety requirements
      • IEC/EN 60950 Information technology equipment – Safety
      • IEC/EN 61180 High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment
      • IEC/EN 61557-14 Electrical safety in low voltage distribution systems up to 1 000 V a.c and 1 500 V d.c - Equipment for testing,measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment for machinery
    • Portable appliances safety
      • PAT Competences: Portable Appliances Safety Testing
      • AWE Competences: Arc Welding Equipment Safety Testing
      • IEC/EN 50106 Safety of household and similar electrical appliances
      • IEC/EN 50144-1 Safety of hand-held electric motor operated tools - Part 1: General requirements
      • EN 50699 Recurrent Test of Electrical Equipment
      • EN 50678 General procedure for verifying the effectiveness of the protective measures of electrical equipment after repair
      • IEC/EN 60335-1 Household and similar electrical appliances - Safety
      • IEC/EN 60598-1 Luminaires - Part 1: General requirements and tests
      • IEC/EN 60745 Hand-held motor-operated electric tools - Safety
      • AS / NZ 3760 In-service safety inspection and testing of electrical equipment
      • VDE 0404-1 Testing and measuring equipment for checking the electric safety of electric devices - Part 1: General requirements
      • VDE 0404-2 Testing and measuring equipment for checking the electric safety of electric devices - Part 2: testing equipment for tests after repair, change or in the case of repeat tests
      • VDE 0701 Inspection after repair, modification of electrical appliances - periodic
      • VDE 0702 Inspection on electrical appliances - general requirements for electrical safety
      • VDE 0661 Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
      • NEN 3140 Guidelines for safe working practices
      • IEC/EN 61029 Safety of transportable motor-operated electric tools
      • IEC/EN 60974 Arc welding equipment series
      • IEC/EN 60974-2 Arc welding equipment - Part 2: Liquid cooling systems
      • IEC/EN 60974-4 Arc welding equipment - Part 4: Periodic inspection and testing
      • VDE 0544 Arc welding equipment series
      • IET COP 5th Ed., In-service Inspection and Testing of Electrical Equipment
    • Mobile Units Electrical Safety
      • eMOB Competences: Electrical LV Installations in Mobile Units Safety
      • IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
      • UN ECE R 100 Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric power train [2015/505]
    • Electrical Vehicle Supply Equipment
      • EVSE Competences: Electrical Vehicle Supply Equipment Safety
      • IEC/EN 61851 Electric vehicle conductive charging system
      • IEC/EN 62752 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
      • IEC/EN 62955 Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles
    • Medical electrical equipment
      • MEDe Competences: Medical Electrical Equipment Safety
      • IEC/EN 62353 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
      • VDE 0751-1 (IEC/EN 62353) Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
      • IEC/EN 60601 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
      • AS/NZS 3551 Management programs for medical devices
    • Medical and surgery rooms' installations
      • MEDi Competences: Medical and Surgery Rooms Electrical Installations Safety
      • IEC/EN 60364-7-710 Requirements for special installations or locations – Medical Location
    • Instrument safety towards user
      • IEC/EN 55022 Information technology equipment - Radio disturbance characteristics
      • EN 55032 Electromagnetic compatibility of multimedia equipment - Emission requirements
      • IEC/EN 61000 Electromagnetic compatibility (EMC) series
      • IEC/EN 61000-2-2 Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
      • IEC/EN 61000-2-4 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
      • IEC 61000-2-12 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
      • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2 - Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
      • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) - Part 3-3 - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
      • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
      • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
      • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
      • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
      • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
      • IEC/EN 61000-4-7 Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
      • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
      • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
      • IEC 61000-6-4:2015 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
      • IEC 61000-6-5:2015 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment
      • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
      • The Low Voltage Directive LVD 73/23/EEC Electrical equipment designed for use within certain voltage limits
      • Directive EMC 2004/108/EC on electromagnetic compatibility
      • Directive EMC 89/336/EE on electromagnetic compatibility
      • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
      • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
      • IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
      • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits
      • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
      • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
    • EMC safety
      • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
      • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
      • IEC/EN 61326-2 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
  • All product groups
    Product groups
    • All product groups
    • Electrical Installations Safety
      • Multifunctional testers
      • Photovoltaic and electrical installation testers
      • Single-functional testers
      • Other instruments / adapters / accessories
    • High Voltage Insulation / Continuity / Earth / Transformer
      • Earth testers
      • Transformer testers
      • Continuity testers
      • High voltage insulation testers
    • Machines / Appliances / Switchgear Safety
      • PAT testers
      • Machine and switchboard testers
      • Medical testers
      • End-of-line safety testing in production
      • Other Instruments / adapters / accessories
    • Power Quality Analysis
      • Class A power quality analysers
      • Class S power quality analysers
      • Power calibrator/simulator
    • Equipment for Laboratories and Schools
      • Demonstration boards LV
      • Demonstration boards EE
      • Power supply & other units
    • Digital Multimeters / Current Clamps / Voltage Testers / Thermal cameras
      • Digital multimeters
      • Clamp meters
      • Thermal cameras
      • Voltage and continuity tester
      • Non contact voltage detectors
    • Software
      • PC Software
      • Android
  • All applications
    Applications
    • All applications
    • Electrical Energetics
      • Power generation
      • Renewable energy sources
      • Power distribution
      • Industrial installations
    • Building Facilities
      • Low voltage electrical installation safety
      • Low voltage earthing and lightning protection
      • Low voltage power quality
      • Special locations 
    • Electrical Equipment
      • Machines safety
      • Portable and fixed appliances 
      • End-of-line safety testing in production
    • Transportation
      • e-Mobility
      • Mobile installations
    • Medical Facilities
      • Hospital earthing and lightning protection 
      • Power supply and power distribution 
      • Surgery rooms or operating theatres
      • Patient recovery rooms and hospital wards
      • Secondary power sources in healthcare
    • Other applications
      • Preventative maintenance
      • Troubleshooting
      • General purpose
  • All standards
    Standards Applied
    • All standards
    • Earthing and lightning protection 
      • LPSinsp Competences: Lightning Protection of Buildings Inspection
      • LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
      • IEC 62305 Protection against lightning - series
      • IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
      • IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
    • Power quality 
      • PQA Competences: Power Quality Analyzing & Reporting
      • IEC/EN 61000-4-15 Electromagnetic compatibility (EMC) – Part 4: Testing and measurement techniques – Section 15: Flickermeter – Functional and design specifications
      • IEC/EN 61000-4-30 Ed. 3.0 Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
      • IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring devices (PMD)
      • IEC 62586-1 Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)
      • IEC 62586-2 Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements
      • IEEE 1459-2010 IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions
      • GOST 33073-2014 Electric energy. Electromagnetic compatibility of technical equipment. Control and monitoring of electric power quality in the public power supply systems
      • NRS 048 ELECTRICITY SUPPLY-QUALITY OF SUPPLY
      • GOST R 54149: 2010 Electric energy. lectromagnetic compatibility of technical equipment. Power quality limits in the public power supply systems
      • IEEE 519 Recommended Practice and Requirements for Harmonic Control in Electric Power Systems
      • EN 50160 Voltage characteristics of electricity supplied by public distribution networks
    • Earthing and Grounding
      • EES Competences: Electrical Energetic Systems Earthing and Grounding Safety
      • HD 637 S1 Power installations exceeding 1 kV a.c.
      • IEEE Guide for Safety in AC Substation Grounding
      • IEEE 81-2012 IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System
      • IEEE 142 Recommended Practice for Grounding of Industrial and Commercial Power Systems
      • IEEE 367-2012 - IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault
      • EN 50522 Earthing of power installations exceeding 1 000 V a.c.
      • RAT 2008 Spanish high-voltage regulation
    • Electrical Energetics
      • EEA Competences: Electrical Energetic Installations with Automatic Trip-Out Ability
      • IEC 60076-1 Power transformers Part 1: General
      • IEC/EN 60909-0 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
      • IEC / EN 60947-2 Low-voltage switchgear and controlgear – Part 2: Circuit-breakers
      • IEC 61869-2 Instrument transformers Part 2: Additional requirements for current transformers
      • IEEE C57.12.90 Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
      • ASTM B 539 Standard Test Methods for measuring Resistance of Electrical connections (Static Contacts)
      • NMEA AB 4-2009 Guidelines for Inspection and Preventive Maintenance of Molded-Case Circuit Breakers Used in Commercial and Industrial Applications
      • El Real Decreto 223/2008 Regulation on technical conditions and safety guarantees in high voltage power lines and their complementary technical instructions ITC-LAT 01 to 09
    • Photovoltaic systems
      • PVV Competences: Photo Voltaic Installations Safety/Quality
      • IEC / HD 60364-7-712 Low Voltage Electrical Installation Safety - Special installtions and locations
      • IEC/EN 62446 Photovoltaic (PV) systems - Requirements for testing, documentation and maintenance
      • IEC/EN 61829 Crystalline silicon photovoltaic (PV) array – On-site measurement of I / V characteristics
    • Building LV Installation
      • EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
      • EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
      • IEC/EN 60364 Electrical Installations for Buildings series
      • IEC/EN 60364-6 Electrical Installations for Buildings - Verification
      • IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock
      • IEC/EN 60364-5-52 Electrical Installations for Buildings - Wiring system
      • IEC/EN 60755 General safety requirements for residual current operated protective devices
      • IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
      • IEC/EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)
      • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
      • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - relevant parts
      • IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
      • IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
      • IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
      • IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
      • IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
      • IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
      • IEC/EN 61557-11 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCM) in TT, TN and IT systems
      • IEC/EN 60364-7 Electrical Installations for Buildings - Requirements for special installations or locations
      • VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
      • AS / NZ 3017 Electrical installations – Verification guidelines
      • AS / NZ 3018 Electrical installations - Domestic installations
      • BS 7671 IEE Wiring Regulations (18th edition)
      • CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC current
    • Electrical switchboards safety
      • ESB Competences: Electrical Switchboards Safety Testing
      • IEC/EN 61439-1 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
      • IEC/EN 62271 High-voltage switchgear and controlgear - series
      • IEC/EN 62271-1 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
      • IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
    • Machine safety
      • MST Competences: Machines Electrical Safety Testing
      • IEC/EN 50191 Erection and operation of electrical test equipment
      • IEC/EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
      • IEC/EN 62368-1 Audio/video, information and communication technology equipment - Part 1:Safety requirements
      • IEC/EN 60950 Information technology equipment – Safety
      • IEC/EN 61180 High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment
      • IEC/EN 61557-14 Electrical safety in low voltage distribution systems up to 1 000 V a.c and 1 500 V d.c - Equipment for testing,measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment for machinery
    • Portable appliances safety
      • PAT Competences: Portable Appliances Safety Testing
      • AWE Competences: Arc Welding Equipment Safety Testing
      • IEC/EN 50106 Safety of household and similar electrical appliances
      • IEC/EN 50144-1 Safety of hand-held electric motor operated tools - Part 1: General requirements
      • EN 50699 Recurrent Test of Electrical Equipment
      • EN 50678 General procedure for verifying the effectiveness of the protective measures of electrical equipment after repair
      • IEC/EN 60335-1 Household and similar electrical appliances - Safety
      • IEC/EN 60598-1 Luminaires - Part 1: General requirements and tests
      • IEC/EN 60745 Hand-held motor-operated electric tools - Safety
      • AS / NZ 3760 In-service safety inspection and testing of electrical equipment
      • VDE 0404-1 Testing and measuring equipment for checking the electric safety of electric devices - Part 1: General requirements
      • VDE 0404-2 Testing and measuring equipment for checking the electric safety of electric devices - Part 2: testing equipment for tests after repair, change or in the case of repeat tests
      • VDE 0701 Inspection after repair, modification of electrical appliances - periodic
      • VDE 0702 Inspection on electrical appliances - general requirements for electrical safety
      • VDE 0661 Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
      • NEN 3140 Guidelines for safe working practices
      • IEC/EN 61029 Safety of transportable motor-operated electric tools
      • IEC/EN 60974 Arc welding equipment series
      • IEC/EN 60974-2 Arc welding equipment - Part 2: Liquid cooling systems
      • IEC/EN 60974-4 Arc welding equipment - Part 4: Periodic inspection and testing
      • VDE 0544 Arc welding equipment series
      • IET COP 5th Ed., In-service Inspection and Testing of Electrical Equipment
    • Mobile Units Electrical Safety
      • eMOB Competences: Electrical LV Installations in Mobile Units Safety
      • IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
      • UN ECE R 100 Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric power train [2015/505]
    • Electrical Vehicle Supply Equipment
      • EVSE Competences: Electrical Vehicle Supply Equipment Safety
      • IEC/EN 61851 Electric vehicle conductive charging system
      • IEC/EN 62752 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
      • IEC/EN 62955 Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles
    • Medical electrical equipment
      • MEDe Competences: Medical Electrical Equipment Safety
      • IEC/EN 62353 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
      • VDE 0751-1 (IEC/EN 62353) Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
      • IEC/EN 60601 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
      • AS/NZS 3551 Management programs for medical devices
    • Medical and surgery rooms' installations
      • MEDi Competences: Medical and Surgery Rooms Electrical Installations Safety
      • IEC/EN 60364-7-710 Requirements for special installations or locations – Medical Location
    • Instrument safety towards user
      • IEC/EN 55022 Information technology equipment - Radio disturbance characteristics
      • EN 55032 Electromagnetic compatibility of multimedia equipment - Emission requirements
      • IEC/EN 61000 Electromagnetic compatibility (EMC) series
      • IEC/EN 61000-2-2 Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
      • IEC/EN 61000-2-4 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
      • IEC 61000-2-12 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
      • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2 - Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
      • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) - Part 3-3 - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
      • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
      • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
      • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
      • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
      • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
      • IEC/EN 61000-4-7 Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
      • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
      • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
      • IEC 61000-6-4:2015 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
      • IEC 61000-6-5:2015 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment
      • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
      • The Low Voltage Directive LVD 73/23/EEC Electrical equipment designed for use within certain voltage limits
      • Directive EMC 2004/108/EC on electromagnetic compatibility
      • Directive EMC 89/336/EE on electromagnetic compatibility
      • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
      • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
      • IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
      • IEC/EN 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits
      • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
      • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
    • EMC safety
      • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
      • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
      • IEC/EN 61326-2 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
Clear filters
Select two or more products to compare

Print
Compare products
  • Company profile
  • Company structure
  • Milestones
  • Certificates
  • Contact Us
  • Metrel Electric Blue

Metrel d.o.o.

Ljubljanska c. 77

SI-1354 Horjul

Slovenia

info@metrel.si

+386 (0)1 7558 200

Follow Us

Download apps

Login

Login

 

Metrel d.o.o.
Ljubljanska c. 77
SI-1354 Horjul, Slovenia
The project is funded: www.eu-skladi.si

Privacy policy | Android Privacy Policy

Copyright © 2002 - 2023 Metrel d.o.o.
Enter random number
44672