SPECIAL INSTALLATIONS TESTING, MAINTENANCE, TROUBLESHOOTING, AIRPORTS, RAILWAY, INDUSTRY, EVSE
There are many applications where test instruments as a standalone units are not sufficient enough to cover their needs. Those applications typically subject to special installations and are covered by external adapters. The reasons for the need of adapter could be:
- 3-phase mains connectors (3-phase active switch adapter);
- Combination of requirements from different special installations (EVSE);
- The need of higher power source, DC impedance testing, industrial RCD (Impedance adapters).
ADVANTAGES
- Earth Leakage Relay (ELR) Trip-out Testing Time and Current;
- Supported ELR types AC, A, B;
- Floating voltmeter for partial contact results;
- Selectable test load (16.6 % to 100 %);
- Improved thermal performance;
- Accessible inputs/outputs for connection of safety testers;
- Portable battery (Li-ion) or mains powered test instrument;
- Automated 3-phase system testing;
- Blackbox design (remote controlled via an Android device).
GENERAL FEATURES
- Hi precision 4-wire 300 A Z Line and Z Loop impedance tester;
- Hi range impedance measurements in 800 V / 16 ... 420 Hz AC networks;
- Hi current dR 300 A 4-wire partial voltage drop and current path resistance measurements;
- Earth Leakage Relay (ELR) testing;
- Ground fault analysis with Contact, Touch and Step Voltage;
- One-Clamp hi current grounding method with clamps (Flex & Iron);
- DC source & line resistance measurements in 3 ... 260 V DC networks;
- Functional, diagnostic and electrical safety testing of EVSE;
- Safety testing of Mode 2 EV cables and Mode 3 EV cables;
- Bluetooth communication with Metrel’s electrical safety testers;
- IP protection: IP65 (case closed), IP54 (case opened);
- Up to CAT IV 600 V (3000 m) safety category.
APPLICATIONS
- Automatic trip-out protection evaluation in case of faults in transformers, generators, turbines, contactors, distribution boards and switchyards whenever energetic loads and sources of protection exceed 200 A;
- Power transformer and motor winding measurement;
- Live Power Transformer Hi Precision 4-wire 300 A Z Line / Loop Impedance Testing;
- Partial Voltage Drops and Partial Clamp Current’s Path Resistance testing;
- Impedance testing of airport's Ground Power Units (GPU), railway systems;
- High accuracy battery resistance testing;
- DC Networks’ and Power Sources’ Line and Loop Resistance testing;
- Testing the integrity of Grounding systems and Lightning systems with High Current grounding method flex & iron One-Clamp method;
- Earth Leakage Relay (ELR/MRCD) testing;
- High current injection ground fault simulation;
- EVSE functional and safety testing;
- Safety testing of 1-phase and 3-phase Mode 2 and Mode 3 EV cables;
- Monitoring of the charging process;
- Automated testing of 3-phase systems.